Method Statement installation of Cable Trays and Ladders
Introduction:
This method statement covers the site installation of the cable tray & ladders and the requirements of checks to be carried out.

Cable trays and ladders:
The Cable Tray system is installed in electrical rooms, plant rooms, and service corridors. This section will guide you through the necessary steps to ensure a successful installation.
Ready to take your skills to the next level? 🚀 Check out our Special Online Courses! 🚀
Gain valuable insights, boost your career, and learn from industry experts.

METHOD OF STORAGE:
All materials received at the site shall be inspected and ensure that the materials are as per the approved material submittal.
Any discrepancies, damages, etc. Shall be notified and reported for further action.
Materials found not suitable for the project are removed from the site immediately.
Cable trays and ladders are stored in a horizontal position on a flat surface with timber support placed at an interval of one meter and covered to protect from moisture and direct sunlight.

METHOD OF PRE-INSTALLATION
Review Approved Shop Drawing.
Begin by reviewing the approved shop drawing, which includes essential details about the Cable trays and ladders layout, length, and location of cable trays and ladders in the building.
Prepare the Materials.
Ensure that the approved material required for tray work will be available.
Proper materials including cable trays, ladders, and associated fittings accessories are withdrawn from stores according to approved shop drawings and good engineering practices.
Materials will be physically verified for damages before being purchased from stores and installed.
The site supervisor will check all relevant documentation and material applicable to the section before the commencement of work.
The site engineer/supervisor will also check that the tools and equipment available comply with contract requirements.
METHOD OF INSTALLATION
Mark Cable trays & ladders Locations
After the civil clearance to proceed with MEP installations, ensure the area is clean and ready to start the works.
Mark the trays and ladders routes as per the approved shop drawing; ensure these are of horizontal & vertical runs only.

Data Management and Reporting
Data Management is the key success of construction projects reporting. This self-study course will teach you using a step by step case…
- 1,680 students
- WhatsApp support group
- Certificate
Co-ordinate the routes, and levels and ensure no clashes with other services.
Maintain enough clearance for cable pulling and any access for future maintenance.
hanging system and supports.
Mark the support, fix the threaded rod supports with appropriate metal plugs, and then fix the ‘L’ angles / Slotted ‘C’ channels with nuts.
A maximum of 1.2 M distance is maintained between the supports to avoid the sagging of trays and ladders. Provide adequate support for bends, branches, and offsets.
Cutting Cable trays and ladders.
Cut the standard length/ladder to the required length with appropriate cutting tools.
Use mushroom head screws on the cable route to avoid the cable insulation damage during pulling.
All the fittings shall be from the manufacturer.
All sharp edges and burrs shall be cleaned for pulling the cables.
Treat the cut & Drilled part with zinc paint-rich paint immediately after cutting and before installation.
Fixing cable Trays and ladders
Sleeves shall be provided at all the wall crossings.
Ensure the installation of trays/ladders is neat and in a straight line. Trim the extra projected supports.
Expansion provision shall be provided at all the building expansion joints and the manufacturer’s instructions for installation shall be followed.
A copper earth link shall be installed at every joint to maintain continuity throughout the installation and Approved fire sealant shall be provided wherever the installation crosses the fire-rated walls.
Provide identification labels as specified to identify the service.
The relationship between cable trays and ladders installation and other activities:
Predecessor | Activity name | Successor |
Masonry works | cable trays and ladders | Masonry works |
Productivity rate for cable trays and ladder installation:
Productivity rate:
meter/day = 100
hour/meter = 0.08
Labor Requirement Per Group:
1 electrician
2 Highly Skilled Labor
1 Helper/ Unskilled labor
Download the Resources of this Article
Method Statement installation of Cable Tray and Ladders 400.75 KB 4168 downloads
Keep growing with Planning Engineer
Learn with a clear path
From Primavera P6 basics to claims, cost control and Power BI. Start with our free courses.
Browse coursesGet help on WhatsApp
Every course comes with a private WhatsApp support group where our team answers your questions.
Join a courseFind planning jobs
84 open planning and project control jobs. Post your resume so employers can find you.
See jobsGet tips by email
Free planning tips, templates and course offers. Unsubscribe any time.








![S-Curve from Primavera P6 [Template]](https://planningengineer.net/wp-content/uploads/2025/03/S-Curve-from-Primavera-P6-Template-600x400.png)